dc.description.abstractL'objectif de ce travail consiste à réaliser à nouveau les mesures nécessaires pour valider la précision de calcul de l’algorithme collapse cône utilisé pour le calcul des plans de traitement des patients par l'accélérateur linéaire Elekta Synergy du Clcc Ouargla. Ces mesures incluent les pourcentages de la dose en profondeur du faisceau de photons émis par l'accélérateur linéaire médical Elekta ainsi que des profils de dose, et des mesures de doses absolues dans des points pour différentes configurations. En comparant les résultats mesurés avec les valeurs calculées, notre travail montre une correspondance significative avec ces valeurs, ce qui confirme la qualité de la mise en service, étape cruciale avant le début du traitementen_US
dc.description.abstractالهدف من هذا العمل هو إجراء القياسات الالزمة مرة أخرى للتحقق من دقة الحساب لخوارزمية مخروط االنهيار المستخدمة لحساب خطط عالج المرضى بواسطة المسرع الخطي سينرجي إلكتا في مركز أمراض السرطان قسم العالج باألشعة ورقلة. تتضمن هذه القياسات النسب المئوية للجرعة العميقة لشعاع الفوتون المنبعث من المسرع الخطي الطبي إلكتا باإلضافة إلى ملفات تعريف الجرعة وقياسات الجرعة المطلقة في نقاط مختلفة. ومن خالل مقارنة النتائج المقاسة مع القيم المحسوبة، يُظهر عملنا توافقً قبل بدء العالج. ا كبي ًرا مع هذه القيم، مما يؤكد جودة التشغيل، وهي خطوة حاسم-
dc.description.abstractThe objective of this work is to once again carry out the necessary measurements to validate the calculation precision of the collapse cone algorithm used for the calculation of patient treatment plans by the Elekta Synergy linear accelerator at Clcc Ouargla. These measurements include percentages of the depth dose of the photon beam emitted by the Elekta medical linear accelerator as well as dose profiles, and absolute dose measurements in spots for different configurations. By comparing the measured results with the calculated values, our work shows a significant correspondence with these values, which confirms the quality of the commissioning, a crucial step before the start of treatment.-
dc.language.isofren_US
dc.publisherUniversité Kasdi Merbah Ouarglaen_US
dc.subjectmesures nécessairesen_US
dc.subjectl'accélérateur linéaire Elekta Synergyen_US
dc.subjectdifférentes configurationsen_US
dc.subjectl'accélérateur linéaire médical Elektaen_US
dc.subjectAAPMen_US
dc.subjectCACen_US
dc.titleValidation de l’algorithme Collapsed Cone par le protocole TRS 430en_US