dc.descriptionMEDICAL PHYSICSen_US
dc.description.abstractUltrasound imaging has been used with great success in many fields, including the medical field, especially in the study of biological tissues. In this work, we focused on distinguishing between stages of fibrosis using mean scatterer size and spectral slope. The results of the study showed the possibility of distinguishing between healthy and fibrotic liver tissue. However, the study did not achieve an accurate determination of the levels of fibrosis, which prompted us to test the mean scatterer sizeand the spectral slope. This achieved a positive result if we exclude the difficulty of distinguishing between the two levels (F1, F4).en_US
dc.description.abstractL'imagerie par ultrasons a été utilisée avec un grand succès dans de nombreux domaines, y compris le domaine médical, en particulier dans l'étude des tissus biologiques. Dans ce travail, nous nous sommes concentrés sur la distinction entre les stades de fibrose en utilisant la taille moyenne des diffuseurs et la pente spectrale. Les résultats de l'étude ont montré la possibilité de distinguer entre les tissus hépatiques sains et fibrotiques. Cependant, l'étude n'a pas permis une détermination précise des niveaux de fibrose, ce qui nous a poussés à tester la taille moyenne des diffuseurs et la pente spectrale. Cela a donné un résultat positif si nous excluons la difficulté de distinguer entre les deux niveaux (F1, F4-
dc.language.isoenen_US
dc.publisherUNIVERSITE KASDI MERBAH – OUARGLAen_US
dc.subjectUltrasounden_US
dc.subjectmean scatterer sizeen_US
dc.subjectspectral slopeen_US
dc.subjectالموجات فوق الصوتيةen_US
dc.subjectالإنحدار الطيفيen_US
dc.subjectمتوسط حجم التشتتen_US
dc.titleEffect of spectral slope and mean scatterer size for discrimination between different stages of hepatic fibrosisen_US
dc.typeThesisen_US