DSpace Collection:
https://dspace.univ-ouargla.dz/jspui/handle/123456789/8150
2024-03-29T00:50:31ZÉvaluation de l’activité antioxydante de quelques dérivés de 1,2-dithiole-3-thiones
https://dspace.univ-ouargla.dz/jspui/handle/123456789/8445
Titre: Évaluation de l’activité antioxydante de quelques dérivés de 1,2-dithiole-3-thiones
Auteur(s): Zehour RAHMANI; Messouda DEKMOUCHE; Mokhtar SAÏDI
Résumé: :The antioxidant properties of two dithiolethiones were evaluated using the auto oxidation of pyrogallol UV–Vis spectrophotometric method to generate radical superoxide anion. Antioxidant activity depends of the concentration of dithiolethione in the medium. Results show that the A enhanced antioxidant properties more than B with percent inhibition 38.81 %.; : Les propriétés antioxydantes des deux dithiolethiones ont été évaluées en utilisant l'autoxydation du
pyrogallol par la spectroscopie UV-Vis pour générer le radical anion superoxyde . L'activité antioxydante dépend de
la concentration de dithiolethione dans le milieu. Les résultats montrent que le composé A a amélioré les propriétés
antioxydantes plus que le composé B avec un pourcentage d'inhibition de 38.81 %.; الخصائص المضادة للأكسدة لاثنين من المركبات الثنائي ثيول الحلقي A و B قدرت باستخدام الأكسدة الذاتية
للبروغالول عن طريق مطيافية UV–Vis لتوليد جذر أنيون فوق الأكسيد . النشاطية المضادة للأكسدة تعتمد على تركيز
الثنائي ثيول الحلقي في الوسط. النتائج أظهرت أن المركب A عزز الخصائص المضادة للأكسدة أكثر من B و ذلك بنسبة تثبيط
. % 38.81
Description: AST Annales des Sciences et Technologie2014-10-01T00:00:00ZCalculation of Electromagnetic Energy radiated by Electric Spark
https://dspace.univ-ouargla.dz/jspui/handle/123456789/8453
Titre: Calculation of Electromagnetic Energy radiated by Electric Spark
Auteur(s): Salima GUERRICHA; Hacen BEN ALI; Smail CHIHI
Résumé: The missed energy during connecting two conducting pellets has been calculated. This energy has been considered as an electrostatic energy stored in charges, an as electromagnetic radiation accompanied by the electric spark, and as thermal enegry of Joule effect. A simple model consists of two conducting pellets has been used. Discharge current is flowing through filiform wire between the two pellets. The radiation energy, the thermal energy of Joule effect and the electrostatic energy remaining in system, have been calculated. The summation of these energies was 77,44 % from the initial energy of the system, while it should be 100%. This disagreement has been attributed to errors caused by the approximations and the computationalmodel thatmight beinaccurate.The lack of acoustic energy associated to the discharge has also been pointed to.; لقد سبت
ُ
َّتين ناقلتين
ح الطاقة المفتقدة أثناء توصيل ي
َ
ببعضهما، باع في الشحنات ُكر
ً
نة
َ
مختز
ً
كهروستاتيكية
ً
تبارها طاقة ، ثم باعتبار ها إشعاعا
َّتين ناقلتين، يحدث بينهما
كهرومغناطيسيا مصاحبا للشرارة الكهربائية التي تحدث عند توصيل الكريتين ببعضهما. ي
َ
ً ُ ا من كر
ا بسيطا مؤلَّف
ً
لقد استخدمنا نموذج
سلك ناقل يربط بينهما
ْ
تفريغ للشحنة عبر . حسبنا طاقة الإشعاع و الطاقة المتبددة بفعل جول الحراري و الطاقة الكهروستاتيكية المتبقية في الجملة. كان مجموع
هذه الطاقات حوالي %77,44 من قيمة الطاقة الابتدائية للجملة قبل التوصيل، في حين كان ينبغي أن تكون %100. أرجعنا ذلك إلى الأخطاء الناجمة عن
التقريبات ا دقيق
َ
لحسابية و النموذج الذي قد يكون غير . لقد أشرنا كذلك إلى عدم احتساب الطاقة الصوتية المصاحبة لتفريغ الشحنة.
Description: AST Annales des Sciences et Technologie2014-10-01T00:00:00ZAdsorption of Cd Ions From Aqueous Solution Onto Date Palm Leaflets Powder:
https://dspace.univ-ouargla.dz/jspui/handle/123456789/8447
Titre: Adsorption of Cd Ions From Aqueous Solution Onto Date Palm Leaflets Powder:; Isotherms, Kinetics and Thermodynamics
Auteur(s): Messaoud GOUAMID; Elyacout CHEBOUAT; Mohammed Ridha OUAHRANI; Mustapha SAIDAT
Résumé: In this study, a series of batch laboratory experiments were conducted in order to investigate the feasibility of date palm leaves powder (DPLP) for the removal of Cadmium from aqueous solution by the adsorption process. Investigation was carried out by studying the influence of initial solution pH, adsorbent dosage and initial concentration of Cadmium, the particle size of (DPLP) and temperature. The single component equilibrium data was analyzed using Langmuir, Freundlich, Dubinin-Radushkevich and Temkin adsorption isotherms. The results showed that equilibrium was reached within 80 min. The used biosorbent gave the highest adsorption capacity at pH 5. The experimental isotherm data were analyzed and modeled. The maximum adsorption capacity, Langmuir’s qmax, improved from 9.80 to 9.90 mg/g as the temperature increased from 15 to 45°C. The enthalpy ΔH° and entropy ΔS° values were respectively estimated at 30.33 kJ mol-1 and 0.156 kJ K-1 mol-1 for the process, the negative value of ΔG° indicates that the adsorption of Cd(II) ions on (DPLP) is a spontaneous process. Three simplified kinetic models including a pseudo-first-order equation, pseudo-second-order equation and intraparticle diffusion equation were selected to follow the adsorption process. Kinetic parameters, rate constants, equilibrium sorption capacities and related correlation coefficients, for each kinetic model were calculated and discussed. It was shown that the adsorption of Cd(II) ions could be described by the pseudo-second order equation, suggesting that the adsorption process is presumable a chemisorption.
Description: AST Annales des Sciences et Technologie2014-10-01T00:00:00ZEtude technico-économique de la production d’hydrogène par deux applications de l’énergie solaire dans la région de Ouargla
https://dspace.univ-ouargla.dz/jspui/handle/123456789/8442
Titre: Etude technico-économique de la production d’hydrogène par deux applications de l’énergie solaire dans la région de Ouargla
Auteur(s): Nasreddine CHENNOUF; Belkhir NEGROU; Noureddine SETTOU; Soumia RAHMOUNI; Boubeheur DOKKAR
Résumé: Facing to the increasingly pressing environmental concerns, such as the control of the emission of gas with greenhouse effect, and facing the exhaustion announced of fossil energies reserves, hydrogen obtained from renewable energies is seen as a promising energy vector. This work focuses on the techno-economic study on the realization of a massive generating station of hydrogen by using two processes of renewable electrical energy to supply an industrial electrolyser of alkaline type. We present the energy modeling of two systems constitute the EnR/H2 installation. The evaluation of the potential of hydrogen production as well as the estimate of the electrolytic hydrogen total costs product is carried out in order to make a comparison unified between the EnR/H2 systems. The results obtained show that the two studied installations are very profitable and have a great potential of production of hydrogen. The studies carried out show that the techno-economic interest of the hydrogen production for one of two technologies suggested depends on the environmental parameters and especially on the production capacity chosen for the design (installation PV/H2 is most interesting for a capacity of 50t/an, on the other hand, the Chimney/H2 for a higher capacity).; Face aux préoccupations environnementales de plus en plus pressantes, telles que la maîtrise des rejets de
gaz à effet de serre, et face à l’épuisement annoncé des réserves d’énergies fossiles, l’hydrogène vert obtenu à partir des
énergies renouvelables est perçu comme un vecteur énergétique prometteur. Ce travail de recherche est une étude
technique et économique sur la réalisation d’une installation de production massive d’hydrogène en utilisant deux
procédés d’énergie électrique renouvelable pour alimenter un électrolyseur industriel de type alcalin. Nous présentons la
modélisation énergétique de deux sous systèmes constituants l’installation Energie Renouvelable à production
d'hydrogène (EnR/H2). L’évaluation du potentiel de production d’hydrogène ainsi que l’estimation du coût total
d’hydrogène électrolytique produit est menée afin de faire une comparaison unifiée entre les systèmes EnR/H2. Les
résultats obtenus montrent que les deux installations étudiées sont très rentables et présentent un grand potentiel de
production d’hydrogène. Les études effectuées montrent que l’intérêt technico-économique de la production
d’hydrogène pour les deux technologies proposées dépend des paramètres environnementaux et surtout de la capacité de
production choisie pour la conception. L’installation PV/H2 est la plus intéressante pour une capacité de 50t/an, par
contre, l’installation Cheminée/H2 est pour une capacité supérieure.; نظرا لتزايد الاهتمامات البيئية خاصة فيما يتعلق بالتحكم في انبعاث الغازات المتسببة في الاحتباس الحراري و لمواجهة نضوب الوقود الاحفوري،
يعتبر الهيدروجين الاخضر المصنع من مصادر الطاقة المتجددة حامل الطاقة للمستقبل. الهدف من هذا العمل هو دراسة جميع العناصر التقنية و الاقتصادية
لإنتاج الهيدروجين بكميات كبيرة عن طريق عملية التحليل الكهربائي للماء باستخدام مصادر ين للطاقة المتجددة. قمنا بتقديم الطريقة المتبعة التي تسمح لنا
بنمذجة جميع الأجزاء المكونة للنظام. و قمنا بتقدير كمية إنتاج الهيدروجين وتحديد تكلفة إنتاجه لكل من المنشآت طاقة متجددة/هيدروجين و ذلك من أجل
القيام بمقارنة متجانسة. النتائج المتحصل عليها أثبتت أنه من أجل قدرة إنتاجية سنوية صغيرة ( 50 )طن ، تعتبر المنشأة الكهرضوئية هي الأحسن، وأكبر من
هذه القدرة تعتبر المدخنة الشمسية/هيدروجين هم الأكثر كفاءة
Description: AST Annales des Sciences et Technologie2014-10-01T00:00:00Z