Title: Study of compression system check valve failure hazards
Authors: Abdelouahab, Gasmi
Saber, Boulifa
Abdelkader, Krobba
Keywords: Check valve
HAZOP
compressor
reverse flow
compressed gas
صمام التدفق الاحادي
الضاغط
التدفق العكسي
غاز مضغوط
Issue Date: 2023
Abstract: The check valve is an important equipment in the context of security and safety at a gas compressor station or gas re-injection. It allows for the passage of compressed gas in the desired direction and prevents the inverse flow of gas which is the result of pressure difference for many factors related to the situation of the compressor operation and the state of the equipment. Therefore, it is necessary to install the check valve as a fixed barrier that supports safety along with automatic systems.
يعتبر صمام الفحص من المعدات الهامة في سياق الامن والسلامة في محطة ضغط الغاز،فهو يسمح بمرور الغاز المضغوط في الاتجاه المرغوب ويمنع التدفق المعاكس للغاز الذي يكون نتيجة فرق الضغط لعدة عوامل مختلفة تتعلق بوضع تشغيل الضاغط وحالة المعدات،لذلك من الضروري تركيب صمام الفحص كحاجز ثابت يدعم السلامة في محطة الضغط الى جانب الانظمة الاتوماتيكية.
Description: Health Safety Environment
URI: https://dspace.univ-ouargla.dz/jspui/handle/123456789/33320