Please use this identifier to cite or link to this item:
https://dspace.univ-ouargla.dz/jspui/handle/123456789/33320
Title: | Study of compression system check valve failure hazards |
Authors: | Abdelouahab, Gasmi Saber, Boulifa Abdelkader, Krobba |
Keywords: | Check valve HAZOP compressor reverse flow compressed gas صمام التدفق الاحادي الضاغط التدفق العكسي غاز مضغوط |
Issue Date: | 2023 |
Abstract: | The check valve is an important equipment in the context of security and safety at a gas compressor station or gas re-injection. It allows for the passage of compressed gas in the desired direction and prevents the inverse flow of gas which is the result of pressure difference for many factors related to the situation of the compressor operation and the state of the equipment. Therefore, it is necessary to install the check valve as a fixed barrier that supports safety along with automatic systems. يعتبر صمام الفحص من المعدات الهامة في سياق الامن والسلامة في محطة ضغط الغاز،فهو يسمح بمرور الغاز المضغوط في الاتجاه المرغوب ويمنع التدفق المعاكس للغاز الذي يكون نتيجة فرق الضغط لعدة عوامل مختلفة تتعلق بوضع تشغيل الضاغط وحالة المعدات،لذلك من الضروري تركيب صمام الفحص كحاجز ثابت يدعم السلامة في محطة الضغط الى جانب الانظمة الاتوماتيكية. |
Description: | Health Safety Environment |
URI: | https://dspace.univ-ouargla.dz/jspui/handle/123456789/33320 |
Appears in Collections: | Département de Génie Appliqué Licence |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
مذكرة كاملة_compressed.pdf | 1,17 MB | Adobe PDF | View/Open |