Please use this identifier to cite or link to this item: https://dspace.univ-ouargla.dz/jspui/handle/123456789/34187
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorBOUHEMAME Nasser-
dc.contributor.authorBERREBEUH, Mohammed Hicham-
dc.contributor.authorBADDOU, Alaeddine Ismail-
dc.date.accessioned2023-09-20T11:39:40Z-
dc.date.available2023-09-20T11:39:40Z-
dc.date.issued2023-
dc.identifier.urihttps://dspace.univ-ouargla.dz/jspui/handle/123456789/34187-
dc.descriptionMaintenance industrielleen_US
dc.description.abstractDans les applications technologiques, la fonction « étanchéité » consiste à séparer deux milieux fluides de nature et/ou d'états physico-chimiques différents, leur but est de minimiser ou d'empêcher une contamination d'un milieu par apport à l'autre, afin d'éviter une pollution, une réaction chimique, une avarie ou surtout une fuite qui conduit à une perte de performances. Dans notre investigation expérimentale sur les pompes de l’huile chaude P5001A/B connaissent un problème d’étanchéité résultant de la défaillance de leurs garnitures mécaniques à cause de formation des dépôts solides à l’intérieure de ces dernières. Un diagnostic judicieux est fait sur ce problème. L’utilisation du diagramme d'Ishikawa, est un diagramme de causes et effets a pour but délimiter les causes possibles puis les causes réelles à partir desquelles on a proposé des solutions. Parmi la solution la plus importante qui influence sur la performance de la pompe, c’est l’élimination des sources d’oxygène.en_US
dc.description.abstractIn technological applications, the "sealing" function consists in separating two fluid media of different nature and/or physicochemical states, their aim is to minimize or prevent contamination of one medium by contribution to the other. , in order to avoid pollution, a chemical reaction, damage or above all a leak which leads to a loss of performance. In our experimental investigation on the P5001A/B hot oil pumps experiencing a sealing problem, resulting from the failure of their mechanical seals due to the formation of solid deposits inside them. A judicious diagnosis is made on this issue. The use of the Ishikawa diagram is a diagram of causes and effects aims to delimit the possible causes then the real causes from which solutions have been proposed. Among the most important solution that influences the performance of the pump is the elimination of oxygen sources.-
dc.language.isofren_US
dc.publisherUniversité KASDI-MERBAH Ouarglaen_US
dc.subjectPompe centrifugeen_US
dc.subjectgarniture mécaniqueen_US
dc.subjectproblème d’étanchéitéen_US
dc.subjectdiagramme d'Ishikawaen_US
dc.subjectCentrifugal pumpen_US
dc.subjectmechanical sealen_US
dc.subjectsealing problemen_US
dc.subjectIshikawa diagramen_US
dc.subjectCentrifugal pumpen_US
dc.subjectmechanical sealen_US
dc.subjectsealing problemen_US
dc.subjectIshikawa diagramen_US
dc.titleAnalyse et diagnostic de garniture mécanique d’une pompe à l’huile chaudeen_US
dc.typeThesisen_US
Appears in Collections:Département de Génie Mécanique - Master

Files in This Item:
File Description SizeFormat 
1687422147497_Mémoire_BERREBEUH Mohammed Hicham_BADDOU Alaeddine Ismail_2023.pdf2,57 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.