Please use this identifier to cite or link to this item: https://dspace.univ-ouargla.dz/jspui/handle/123456789/15299
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorARBAOUI Nacereddine-
dc.contributor.authorAouadi, Houssem Eddine-
dc.date.accessioned2017-07-06T09:26:00Z-
dc.date.available2017-07-06T09:26:00Z-
dc.date.issued2017-
dc.identifier.urihttp://dspace.univ-ouargla.dz/jspui/handle/123456789/15299-
dc.descriptionGénie des Procédésen_US
dc.description.abstractLa récupération de pétrole brut au niveau de la direction régionale de TFT est régie par le bon fonctionnement du système de gaz lift, afin de maintenir les potentiels de productions des puits dont le but d’avoir un plateau de production stable. Le gaz lift est produit dans l’unité de traitement du gaz associé, après sa déshydratation et sa compression est envoyée vers les puits producteurs de pétrole qui sont équipés d’une complétion conventionnelle du gaz lift. Pour assurer le bon fonctionnement de la section de déshydratation de l’UTGA, il m’a été demandé de faire une étude de vérification des paramètres de fonctionnement des sécheurs D301A/B/C avec les conditions actuelles et de voir l’effet du changement des tamis moléculaires 1/16’’ par 1/8’’ sur le fonctionnement de ces derniers. Pour remédier à la problématique de TFT en termes de la teneur en eau dans le gaz lift, nous avons procédé à l’étude avec proposition des solutions adéquates permettant de résoudre ce problème et avec réalisation facile.en_US
dc.description.abstractThe petrol recuperation in TFT regional direction is a function of gas lift system using in order to maintain the potential of wells production and to obtain a stable production. The gas lift is produced in UTGA unit (unit of associated gas treatment), after its dehydration and its compression, is sent and dispatched towards the TFT producers oil wells, which are equipped with a conventional gas, lift completion. For insuring the smooth running of dehydration section of the UTGA, it was asked to me to make a study, for checking the running parameters of dryers D301A/B/C with the current conditions and to see the effect of the change in molecular sieves diameter from 1/16’’ to 1/8’’ on the dryers functioning. For solving the problem of the outlet gas humidity, we have proceeded to the study with the proposal and easy solutions in site realization.-
dc.language.isofren_US
dc.relation.ispartofseries2017;-
dc.subjectRecoveryen_US
dc.subjectDryeren_US
dc.subjectGas liften_US
dc.subjectPotentialen_US
dc.subjectDehydrationen_US
dc.subjectMolecular sievesen_US
dc.subjectRécupérationen_US
dc.subjectGaz liften_US
dc.subjectPotentielen_US
dc.subjectDéshydratationen_US
dc.subjectTamis moléculaireen_US
dc.subjectSécheuren_US
dc.titleOptimisation de Cycle des Sécheurs D-301A/B/C de TFTen_US
dc.typeThesisen_US
Appears in Collections:Département de Génie des procédés - Master

Files in This Item:
File Description SizeFormat 
Aouadi-Houssem-Eddine.pdf5,53 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.