Title: calcul des protections d’un départ HTA (30 KV)
Authors: DJEDDI Abdelghani
BEN DERRADJI, Selsabil
Keywords: Protection
Distribution électrique
Moyenne tension
Maximum de courant
Issue Date: 2014
Series/Report no.: 2014;
Abstract: L’utilisation de l’énergie électrique est parfois très dangereuse, pour cela, on trouve des protections installées au niveau des postes de transformations, et qui servent à la commande et à l’isolation de la ligne en cas de danger. Notre travail consiste au calcul des valeurs des réglages qui doivent être programmées dans ces protections. On trouve dans le marché plusieurs marque de protections, plusieursmarques des transformateur de courant, pour cela, on doit vérifier les équipements déjà installé, et on doit surtout vérifier le couplage (le raccordement des TC), et on doit prendre en considération les caractéristiques techniques des lignes électriques déjà réalisées et raccordées avec la ligne concernée par le calcul des réglages. On doit aussi vérifier les modes de fonctionnement de ces lignes en cas de défauts et dans le cas sain. Un bon calcul des réglages assurent un bon fonctionnement de la fourniture de l’énergie électriques, d’une manière permanente et sans perturbations.
The use of electrical energy usually seems dangerous. For that reason, we find in all stations the electric protection system which is used in controlling and separating the transferring electrical wires in case danger arises. This thesis depends upon counting the results of the modulation (adjustment) which should be programmed within the systems of protection. In markets, we would find various brands for these systems, and many others for the current transferors. For this reason, there should be serious monitoring over the formerly fixed equipment, and in particular connecting monitoring (current transferors interconnection) and taking into account the technical characteristics of the formerly checked transferring wires and which are connected to the wire in question according to counting the modulations (adjustments). Also, we must confirm (recognize) the ways of how to start up (automate) these wires in case of flaws as well as in normal cases
URI: http://dspace.univ-ouargla.dz/jspui/handle/123456789/5295
Appears in Collections:Département de Génie électrique - Master

Files in This Item:
File Description SizeFormat 
BENDERRADJI_Selsabil.pdf2,67 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.