Title: Analyse et diagnostic de garniture mécanique d’une pompe à l’huile chaude
Authors: BOUHEMAME Nasser
BERREBEUH, Mohammed Hicham
BADDOU, Alaeddine Ismail
Keywords: Pompe centrifuge
garniture mécanique
problème d’étanchéité
diagramme d'Ishikawa
Centrifugal pump
mechanical seal
sealing problem
Ishikawa diagram
Centrifugal pump
mechanical seal
sealing problem
Ishikawa diagram
Issue Date: 2023
Publisher: Université KASDI-MERBAH Ouargla
Abstract: Dans les applications technologiques, la fonction « étanchéité » consiste à séparer deux milieux fluides de nature et/ou d'états physico-chimiques différents, leur but est de minimiser ou d'empêcher une contamination d'un milieu par apport à l'autre, afin d'éviter une pollution, une réaction chimique, une avarie ou surtout une fuite qui conduit à une perte de performances. Dans notre investigation expérimentale sur les pompes de l’huile chaude P5001A/B connaissent un problème d’étanchéité résultant de la défaillance de leurs garnitures mécaniques à cause de formation des dépôts solides à l’intérieure de ces dernières. Un diagnostic judicieux est fait sur ce problème. L’utilisation du diagramme d'Ishikawa, est un diagramme de causes et effets a pour but délimiter les causes possibles puis les causes réelles à partir desquelles on a proposé des solutions. Parmi la solution la plus importante qui influence sur la performance de la pompe, c’est l’élimination des sources d’oxygène.
In technological applications, the "sealing" function consists in separating two fluid media of different nature and/or physicochemical states, their aim is to minimize or prevent contamination of one medium by contribution to the other. , in order to avoid pollution, a chemical reaction, damage or above all a leak which leads to a loss of performance. In our experimental investigation on the P5001A/B hot oil pumps experiencing a sealing problem, resulting from the failure of their mechanical seals due to the formation of solid deposits inside them. A judicious diagnosis is made on this issue. The use of the Ishikawa diagram is a diagram of causes and effects aims to delimit the possible causes then the real causes from which solutions have been proposed. Among the most important solution that influences the performance of the pump is the elimination of oxygen sources.
Description: Maintenance industrielle
URI: https://dspace.univ-ouargla.dz/jspui/handle/123456789/34187
Appears in Collections:Département de Génie Mécanique - Master

Files in This Item:
File Description SizeFormat 
1687422147497_Mémoire_BERREBEUH Mohammed Hicham_BADDOU Alaeddine Ismail_2023.pdf2,57 MBAdobe PDFView/Open