Please use this identifier to cite or link to this item:
https://dspace.univ-ouargla.dz/jspui/handle/123456789/42141| Title: | Machine Learning in Medical Imaging |
| Authors: | Ouezzani, Ouassim Debba, Ahmed djad Abdelghani, Manseur |
| Keywords: | Machine Learning Convolutional Neural Network (CNN) upport Vector Machine (SVM) Medical Imaging Brain Tumor Classification MRI HOG Features Computer-Aided Diagnosis |
| Issue Date: | 2026 |
| Publisher: | UNIVERSITY OF KASDI MERBAH OUARGLA |
| Citation: | FACULTY OF NEW TECHNOLOGIES OF INFORMATION AND COMMUNICATION+ |
| Abstract: | Medical imaging has become a cornerstone of modern clinical practice, enabling non-invasive visualization of internal anatomical structures and supporting accurate disease diagnosis. The rapid growth in both the volume and complexity of medical image data — particularly from Magnetic Resonance Imaging (MRI) — has created an urgent need for intelligent automated analysis tools capable of assisting clinicians in detection, classification, and patient monitoring. This thesis addresses the problem of brain tumor classification from MRI data using two complementary machine learning approaches: a lightweight custom Convolutional Neural Network (CNN) designed and implemented in MATLAB, and a Support Vector Machine (SVM) baseline employing Histogram of Oriented Gradients (HOG) feature extraction combined with a Radial Basis Function (RBF) kernel. Both models were evaluated under identical CPU-only experimental conditions (Intel CPU, 8 GB RAM, no GPU) using the same dataset, preprocessing pipeline, and evaluation protocol. The study utilizes a publicly available binary-labeled MRI dataset comprising 9,043 images (2,556 Normal; 6,487 Tumor). Five-fold cross-validation was applied, and performance was measured using accuracy, precision, recall, specificity, and F1-score. The CNN achieved 98.75% accuracy, 99.48% precision, 96.22% recall, 99.79% specificity, and 97.82% F1-score, substantially outperforming the SVM (85.44% accuracy, 65.32% F1-score) across most metrics. However, the SVM attained perfect recall (100%), missing no tumor case, while training in approximately 15 minutes compared to 35 minutes for the CNN. These results demonstrate the complementary strengths of deep learning and classical machine learning: CNN is preferable for high-accuracy clinical diagnosis, while SVM is suited to resource-constrained environments and initial medical screening |
| Description: | Telecommunication Systems |
| URI: | https://dspace.univ-ouargla.dz/jspui/handle/123456789/42141 |
| Appears in Collections: | Département des télécommunications et contrôle Mastériales |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Ouezzani-Debba | Telecommunications Systems | 912 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.