Please use this identifier to cite or link to this item: https://dspace.univ-ouargla.dz/jspui/handle/123456789/41998
Title: Analyse des risques liés au fonctionnement d`une colonne par application de la méthode HAZOP (cas oued noumer)
Authors: LABIADH, Abd Elhammid
ATI, Mohammed Tahar
BEN RAMDANE, Chouaib
CHIROUBA, Mohammed El Amine
MOKADAM, Mohammed
Keywords: Gestion des risques industriels
Matières inflammables
HAZOP
Industrial Risk Management
Flammable materials
إدارة المخاطر الصناعية
مواد قابلة للإشتعال
Issue Date: 2026
Publisher: INSTITUT DE TECHNOLOGIE
Abstract: Dans le contexte du développement continu des industries pétrolières et gazières, la gestion des risques industriels est devenue un élément fondamental pour garantir la sécurité des personnes, des installations et la protection de l’environnement. Les installations hydrocarbures se caractérisent par la présence de nombreux dangers liés aux opérations d’exploitation, en raison de l’utilisation de substances inflammables ainsi que de conditions de pression et de température élevées. Cela nécessite l’adoption de méthodes efficaces d’analyse et d’évaluation des risques afin de mieux les maîtriser et de réduire leurs impacts potentiels. La présente étude porte sur l’application de la méthodologie d’analyse des risques HAZOP à la colonne de déméthanisation (40-C-01) au sein de l’unité de traitement du gaz et du pétrole du complexe d’Oued Noumer appartenant à la société SONATRACH. Cette étude vise à identifier les différentes déviations opérationnelles liées aux principaux paramètres de fonctionnement tels que la pression, la température, le débit et le niveau, ainsi qu’à analyser leurs causes et leurs conséquences potentielles sur la sécurité du procédé industriel.
In the context of the continuous development of the oil and gas industries, industrial risk management has become one of the fundamental elements for ensuring the safety of personnel, facilities, and environmental protection. Hydrocarbon installations are characterized by the presence of numerous hazards associated with operating processes due to the use of flammable substances, as well as high- pressure and high-temperature conditions. This requires the implementation of effective methods for risk analysis and assessment in order to control these risks and minimize their potential impacts. This study focuses on the application of the HAZOP risk analysis methodology to the Euthanizer Column (40-C-01) within the gas and oil processing unit of the Oued Noumer complex operated by SONATRACH. The objective of this study is to identify the various operational deviations related to the main operating parameters such as pressure, temperature, flow rate, and level, and to analyze their causes and potential consequences on the safety of the industrial process.
في سياق التطور المستمر لصناعات النفط والغاز، أصبحت إدارة المخاطر الصناعية أحد العناصر األساسية لضمان سالمة األفراد والمنشآت وحماية البيئة. تتميز منشآت المحروقات بوجود العديد من األخطار المرتبطة بعمليات التشغيل،وذلك بسبب استعمال المواد القابلة لالشتعال، إضافة إلى ظروف الضغط ودرجة الحرارة المرتفعة. وهذا ما يتطلب تطبيق أساليب فعالةلتحليل وتقييم المخاطر من أجل التحكم فيها والتقليل من آثارها المحتملة. تركز هذه الدراسة على تطبيق منهجية تحليل المخاطرHAZOPعلىعمود نزعاإليثان(-(40. C.01ضمن وحدة معالجة الغاز والنفط بمركب وادي النمر التابع لشركةSONATRACH.وتهدف هذه الدراسة إلى تحديد مختلف االنحرافات التشغيليةالمتعلقة بمتغيرات التشغيل الرئيسية مثل الضغط ودرجة الحرارة ومعدل التدفق والمستوى، مع تحليل أسبابها والنتائج المحتملة المترتبة عنها على سالمة العملية الصناعية.
Description: Hygiène, Sécurité et Environnement. (HSE)
URI: https://dspace.univ-ouargla.dz/jspui/handle/123456789/41998
Appears in Collections:Département de Génie Appliqué Licence

Files in This Item:
File Description SizeFormat 
Analyse des risques liés au fonctionnement d`une colonne par application de la méthode HAZOP (cas oued noumer).pdfHygiène, Sécurité et Environnement. (HSE)1,14 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.